Formulation Lab
Built for the formulator's bookmarks bar.
Per-active analytical scope, INCI verification, recommended use levels, carrier-compatibility guidance, and stability data — the references a cosmetic chemist actually wants on tap when designing a serum, cream, or eye-area finished product.
Sample lot PD-26-A0517 · Copper Tripeptide-1 · Pepoderma atelier · Shanghai
Documented like a paper, sold like an active
Every batch, fully documented.
Every shipment leaves the atelier with the batch's Certificate of Analysis, HPLC purity, mass-spec identity, and microbial limits. INCI verification, stability data in our reference aqueous serum, and copper-content verification (for copper-peptide actives) are included so a chemist answers their own QA before the first sample fills a laboratory beaker.
≥99%
HPLC + ESI-MS purity
100%
Batches with COA
<12h
First response
INCI verification + CAS reproduced on every SDS so cosmetic-notification workflows (CPNP, equivalent) run in parallel.
RP-HPLC + ESI-MS on every batch, plus copper-content verification on the copper-peptide actives by atomic absorption.
Stability in our reference aqueous serum documented per active; accelerated and long-term data available on request.
Analytical methods · on every lot
What every Pepoderma release is tested for.
The release scope below runs on every commercial cosmetic- grade lot. Method provenance follows USP <621> (HPLC), EP cosmetic-ingredient frameworks, and ICH Q2 method validation. The lot report carries the numerical value, the method line, and the release decision against the documented target.
| Test | Method | Target |
|---|---|---|
| RP-HPLC purity | C18 gradient with UV detection at the active's working wavelength | ≥ 98.0 % (cosmetic-grade spec) |
| ESI-MS identity | ESI-MS, monoisotopic [M+H]⁺ vs. theoretical | Confirmed (±0.5 Da) |
| INCI verification | Cross-reference against EU CosIng + US PCPC INCI databases | Listed INCI · SDS bound |
| Water content (Karl Fischer) | Coulometric KF | ≤ 8.0 % (lyophilised powder) |
| Counter-ion | Ion chromatography | Acetate (default) |
| Stability — reference aqueous serum | Time-course RP-HPLC at 25 °C / 40 °C over 12 months | Documented decay envelope; ≥ 90 % retention at 6 months / 25 °C |
| Photo-stability flag | Light-stress study (ICH Q1B-style) | Flagged on the lot report when relevant |
Documentation
Everything a cosmetic R&D chemist needs.
Every lot ships with the documentation panel on the right. On request we provide raw HPLC chromatograms, ESI-MS spectra, the extended stability series, and the SDS bundled with the verified INCI name for cosmetic notification workflows.
Lot Report
Per-lot release document with HPLC purity, ESI-MS identity, water content, counter-ion, and stability flag.
RP-HPLC chromatogram
Raw chromatogram showing main peak + integrated impurity profile.
ESI-MS spectrum
[M+H]⁺ confirmation within ±0.5 Da of theoretical INCI molecule.
Stability data
Reference aqueous-serum stability across 25 °C / 40 °C through 12 months on the lot report; brand-carrier study scoped per inquiry.
INCI + CAS SDS
Verified INCI name and CAS on the lot SDS, ready for cosmetic-notification workflows (CPNP, NMPA, equivalents).
Carrier-compatibility note
Active-specific flags: chelator-free water, working pH range, reductive-antioxidant placement, preservative-system compatibility.
Let's talk peptides.
First response under 12 hours · Catalog · Sample COA · MOQ · Lead time. Our regulatory and atelier teams review every inquiry before pricing.